Carboxymethyl cellulose is used in food systems as a thickener, a stabiliser and a suspending agent, and the grades differ in two properties that matter: viscosity and degree of substitution. Everything else in a food grade specification is a purity limit.
Reading the viscosity table
The food grade range covers seven grades in three viscosity bands. LV22 and LV22HDS sit at 25 to 400 mPa·s on a 2% aqueous solution, LV212 sits at 400 to 2000 mPa·s on a 2% aqueous solution, and HV14HDS sits at 200 to 500 mPa·s on a 1% aqueous solution. The remaining grades HV112 and HV125 sit at 500 to 2000 mPa·s and 2000 to 3000 mPa·s on a 1% aqueous solution, with HV130 at 3000 mPa·s and above.
Note the two concentration bases. The 2% and 1% figures are not interchangeable in a straight comparison, and a formulation moved from one group to the other needs a dosage check rather than a number substitution.
What degree of substitution changes
Degree of substitution measures how many of the cellulose backbone's hydroxyl groups have been substituted with a carboxymethyl group. LV22HDS reaches a minimum of 1.00, while LV212, HV14HDS and the remaining grades sit at 0.92, 0.90 and 0.90. Higher substitution gives better water solubility and typically better acid stability, and it is the reason LV22HDS is offered as a distinct grade rather than as a viscosity step.
The purity and microbiological limits
Every grade in the range carries the same set of limits: purity 99.50% minimum, chloride as Cl 0.50% maximum, sodium glycolate 0.40% maximum, loss on drying 8.00% maximum, pH 6.5 to 8.5 on a 10 g/L aqueous solution, arsenic 2.00 mg/kg maximum and lead 2.00 mg/kg maximum. The microbiological limits are total plate count 500 cfu/g maximum, moulds and yeasts 100 cfu/g maximum, and E. coli, Salmonella and Staphylococcus aureus not detected.
How to use this in a formulation
Pick the viscosity band from the thickening behaviour your system needs, then pick the substitution level from the acid stability and solubility your process imposes. In most food applications the deciding factor is not the grade itself but how the product is hydrated, since incomplete dispersion gives lumps that no amount of mixing later will remove.
Where to go next
Ask us for the grade specifications and the supporting documents for the food grade CMC you are evaluating; each grade is supplied with a technical data sheet and a certificate of analysis for the batch.